HES AIR EVI NB. External units. General characteristics

ModelUnit of measurementSpecifications
External unitHES-AIR-EVI-i-24-A-О-4HES-AIR-EVI-i-36-A-О-6HES-AIR-EVI-i-100-A-О-6
Maximum number of connected internal unitspcs235
Nominal refrigerating capacityW5300 (2000- 5830)7900 (2300- 8690)12000 (2770- 12700)
Nominal heating capacityW5600 (2210- 6160)8200 (2450- 9020)13000 (2960- 12800)
Nominal demanded power in cooling modeW1750 (280- 2300)2460 (560- 3400)3600 (800- 4200)
Nominal demanded power in heating modeW1540 (280- 2300)2270 (560- 3400)3650(730- 3800)
Nominal current in cooling modeA7,6010,716,0
Nominal current in heating modeA6,709,8016,50
ELECTRIC POWER SUPPLYPh / V~ / Hz1/230/50
3/380/50
Air volume (fan speed: high/med/low)m3/h210027006400
Noise leveldB (а)555857
FREON TYPE R410 A
Factory filling weightkg1,351,403,40
Outside operation temperature range (Cooling/Heating)°С-15 +43 / -25 +24
DIMENSIONS AND WEIGHT
External unitW/D/H, mm800/348/715834/328/6551120/1510/400
External unitkg36,046,097,0

HES AIR EVI. Channel models. General characteristics

ModelUnit of measurementSpecifications
External unitHES-AIR-EVI-i-9-MQ-4HES-AIR-EVI-i-12-MQ-4HES-AIR-EVI-i-18-MQ-4
Nominal refrigerating capacityW260036005100
Nominal heating capacityW290040005800
Nominal demanded power in cooling modeW4575137
Nominal demanded power in heating modeW4575137
Nominal current in cooling modeA0,210.340.63
Nominal current in heating modeA0,210.340.63
ELECTRIC POWER SUPPLYPh / V~ / Hz
1/230/50
Air volume (fan speed: high/med/low)m3/h420/336/294580/464/406860/688/602
Noise leveldB (а)30/26/2332/28/2538/35/32
DIAMETERS OF TUBES
Liquid tubemmØ 6,35Ø 6,35Ø 6,35
Gas tubemmØ 9,52Ø 9,52 (Ø 12,70)Ø 9,52 (Ø 12,70)
DIMENSIONS AND WEIGHT
Internal unitW/D/H, mm840х465х185840х465х185840х465х185
Internal unitkg16,517,521,0

HES AIR EVI V. Cassette 4-direction models. General characteristics

ModelUnit of measurementSpecifications
External unitHES-AIR-EVI-i-9-MK-4HES-AIR-EVI-i-12-MK-4HES-AIR-EVI-i-18-MK-4
Decorative panelHES AIR DP13HES AIR DP13HES AIR DP13
Nominal refrigerating capacityW280036005000
Nominal heating capacityW300039005600
Nominal demanded power in cooling modeW707070
Nominal demanded power in heating modeW707070
Nominal current in cooling modeA0,320,320,32
Nominal current in heating modeA0,320,320,32
ELECTRIC POWER SUPPLYPh / V~ / Hz
1/230/50
Air volume (fan speed: high/med/low)m3/h420/336/294700/600/530700/600/530
Noise leveldB (а)45/41/3545/41/3545/41/35
DIAMETERS OF TUBES
Liquid tubemmØ 6,35Ø 6,35Ø 6,35
Gas tubemmØ 9,52Ø 9,52Ø 9,52 (Ø 12,70)
DIMENSIONS AND WEIGHT
Internal unitW/D/H, mm570/570/260570/570/260570/570/260
Decorative panelW/D/H, mm650х650х55650х650х55650х650х55
Internal unitkg18,018,018,0
Decorative panelkg2,22,22,2

HES AIR EVI W. Wall models. General characteristics

ModelUnit of measurementSpecifications
External unitHES-AIR-EVI-i-9-MW-4HES-AIR-EVI-i-12-MW-4HES-AIR-EVI-i-18-MW-4
Nominal refrigerating capacityW255035005300
Nominal heating capacityW265035005400
Nominal demanded power in cooling modeW404063
Nominal demanded power in heating modeW404063
Nominal current in cooling modeA0,200,200,30
Nominal current in heating modeA0,200,200,30
ELECTRIC POWER SUPPLYPh / V~ / Hz
1/220-240/50
Air volume (fan speed: high/med/low)m3/h6506501000
Noise leveldB (а)414248
DIAMETERS OF TUBES
Liquid tubemmØ 6,35Ø 6,35Ø 6,35
Gas tubemmØ 9,52Ø 9,52Ø 12,70
DIMENSIONS AND WEIGHT
Internal unitW/D/H, mm800/300/198800/300/198970/315/235
Internal unitkg9912,5

Designation structure

Split system type

Multi

HES AIR Source heat pump controller

Is designed to control air conditioning systems in residential, commercial, office and industrial buildings.
The controller allows for the most effective resources consumption to improve the coefficient of the system efficiency.
The controller maintains control over the multifunctional systems with the option of selecting both: separate units and all the units at once:

  • Heating mode
  • Cooling mode
  • Ventilation mode
  • Smart mode of controlling indoor space dehumidification
  • Control of up to 128 units cascade
  • IR remote control for each internal unit